Sodera LE Capture Options Dialog

The Capture Options dialog is used to configure the Sodera LE unit prior to data capture. The capture options are stored on the Sodera LE hardware and these setting will persist until changed. The Capture Options dialog is only active when a Sodera LE unit is connected to the computer running the Frontline software.

Note: if a Sodera LE hardware unit is not connected then these settings can neither be viewed nor changed.

Clicking on OK will save the Capture Options settings on the connected Sodera LE unit. Any Capture Options parameter changes made will overwrite the previously saved Capture Options.

Wireless tab

Sodera LE Capture Options dialog - Wireless devices tab

Sodera LE Capture Options - Wireless tab.

 

Sodera LE Capture Options - Wireless Tab Selections
Section Selection Description
PHY Options  1M and 2M LE Capture and record at 1 Mbps or 2 Mbps.
1M and Coded PHY/Long Range LE Allows for capture of Long Range Bluetooth low energy, also called Coded PHY. Long Range LE can only be captured at 1 Mbps.

General Tab

Sodera LE  Capture Options General Tab

Sodera LE Capture Options - General Tab

Sodera LE Capture Options - General Tab Selections
Section Selection Description
Gain Control Automatic Attenuation The Sodera LE unit will automatically adjust the gain of the received RF signal to estimated levels suitable for effective data capture..
Manual Attenuation

Manual Selection of gain may be necessary if the capture does not provide reliable results. Gain can be adjusted from 0 to 32 dB in 1 dB steps. For example, in the presence of a strong Wi-Fi signal the user may have to increase the attenuation to achieve a reliable Bluetooth low energy data capture. The user should adjust the attenuation and then capture the data again. Repeat, if necessary, until a reliable data capture is acheived..

Manual Attentuation control