RFCOMM Override Decode Information

The Set Subsequent Decoder Parameters dialog allows the user to override an existing parameter at any frame in the capture where the parameter is used.

If you have a parameter in effect and wish to change that parameter:

  1. Set Subsequent Decoders RFCOMMSelect the frame where the change should take effect, and select Set Subsequent Decoder Parameters from the Options menu, or by selecting a frame in the frame display and choosing from the right-click pop-up menu, and make the needed changes.
  2. Change the RFCOMM parameter by selecting from the Change the Selected Item to Carry drop down list.
  3. If you wish to remove an overridden rule click on Remove Override button. If you want to remove all decoder parameter settings click on Remove All.
  4. Choose the protocol the selected item carries from the drop-down list, and click OK.

Each entry in the Set Subsequent Decoder Parameters dialog takes effect from the specified frame onward or until redefined in this dialog on a later frame.

 

RFCOMM Set Item To Carry

Set Subsequent Decoder Parameters selection list

Note: If the capture has no user defined overrides, then the system displays a dialog stating that no user defined overrides exist.